SCUPS® Model 1027 Super Capacitor Uninterruptible Power Supply

Base Price $419.00 /Ea
Catalog No. 301027
Model No. 1027
Configuration Encased in 7.760" x 4.550" x 1.550" Box
Quantity
 
Description Accessories Related Products Recently Viewed
SCUPS® Model 1027 Super Capacitor Uninterruptible Power Supply

  • Provides critical power backup for remote locations.
  • Recognized for significant advantages over battery UPS systems.
  • Low Maintenance, Long Life Service, Wide Temperature Range

SCUPS® Model 1027 Super Capacitor Uniterruptible Power Supply

The SCUPS® Model 1027 Super Capacitor Uninterruptible Power Supply  is designed to provide backup DC power to a nominal 12VDC system in the event that the primary power supply is interrupted.  Loss of the primary power supply is automatically detected and DC power is then supplied from the SCUPS®.  Once the primary power is restored, it is routed to the load and used to recharge the super capacitor in the SCUPS®

The use of the super capacitor for energy storage provides a very low maintenance solution with extremely high cycle life and without the shelf life concerns of the typical battery backup systems. 

The SCUPS® is perfect for low power remote systems where primary power can be interrupted.  Typical applications include remote locations with intermittent grid power or renewable energy systems such as solar powered systems.  The SCUPS® Model 1027 is easily integrated into user equipment or can be supplied in a standalone package.

 SPECIFICATIONS:

  • Max Power to Load:
    • 12W, 12 VDC at 1A
  • Max Primary Load Voltage:
    • 15 VDC
  • Voltage during Hold up:
    • 11.6 VDC
  • Hold Up Time:
    • 14 minutes with 1A Load
    • 29 minutes with 0.5A Load
  • Full Recharge Time:
    • 103 minutes from full discharge to full charge
  • Min. Recharge Time:
    • 37 minutes from full discharge (nominal times at 22°C)
  • Energy Storage:
    • Lithium Ion Super Capacitor
  • Status Signals:
    • Digital: 2-State of Charge, Primary-ON, Backup-ON
  • Temperature:
    • -25°C to 65°C 
  • Dimensions:
    • 7.760" x 5.550" x 1.550" (includes super capacitor) 
  • Weight: 
    • 1.8 lb (includes super capacitor)

SCUPS® Model 1026 Super Capacitor Uninterruptible Power Suppy

 Detailed User Manual Included with SCUP™ Model 1027 and Model 1026.

Table of Contents

  • Introduction
    • Figure 1: Block diagram of ESL Super Capacitor-based UPS unit. 

SCUPS® Model 1027 Block Diagram

  • Caution
  • UPS Integration Wiring Diagram Figure 2; UPS integration wiring diagram
  • Power Connector
  • Activating the UPS
  • Deactivating the UPS
  • UPS System Operations
    • Figure 3: Super capacitor state of charge during UPS system discharge/charge cycle.
       
      Figure 3: SCUPS Model 1027 Discharge/Charge Cycle Diagram.

       
    • Figure 4: Voltage applied to load durng a primary voltage supply fault event.

      Figure 4: Voltage applied to the load during a primary voltage supply fault event. 
       
  • Adjusting UPS Output Voltage Level
  • Hardware Specifications
  • Performance Specifications
  • UPS Discharge Characteristics
    • Figure 5: ESL UPS Energy Discharge Operating Envelope for Current System Release.
       
      Figure 5: ESL UPS Energy Discharge Operating Envelope for Current Release System

    • Figure 6: UPS system discharge time and state of discharge with 500 mA load for different voltages.
       

      Figure 6: UPS system discharge time and state of discharge with 500 mA load for different load voltages.

    • Figure 7: UPS system  discharge time and state of discharge at 1000 mA load for different load voltages.

      Figure 6: UPS system discharge time and state of discharge with 1000 mA load for different load voltages.

  • UPS Charge Characteristics.
    • Figure 8: Charge versus state of charge

      Figure 8: Charge versus state of charge. (3.80 V Charge Voltage)

  • UPS Circuit Board Description
  • Digital Signal Pin out
  • Digital Output Component Specifications
  • Specifications
  • Important Notices
  • Agreement not to Analyze or Reverse Engineer
  • SAFETY INFORMATION: Advisement to Read and Understand Lithium Ion Capacitor Operational Manual
  • Covering Safety Issues
  • Limit of Liability

 All ESL products are available for export.

All data switches, fiber optic interface converters, data communication products, and data acquisition products are subject to a one year warranty against manufacturing defects.  The limit of ESL liability is limited to the cost of the ESL product provided.

*Prices of online are subject to change and verification.

Print this Page
Ask a Product Question
Customer Reviews

Designed and Developed by Brave River Solutions
Home  |  About  |  Press  |  Sales  |  Products  |  R & D  |  R&D Users  |  Downloads  |  Catalog  |  Jobs  |  Contact
Processed page in 0.21875 seconds
Copyright©2018 Electro Standards Laboratories